<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-09 15-17-43
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.20 MHz 5/5, 59 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz 3.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 71 kHz 17063 0,0352
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
5,0 dBr 6,04 dBr 6,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 2 15:17, 9.05.2024
RT
"RMC BLOIS 107.2 "
AF EON
90.1, 90.2, 93.7, 95.3, 96.5, 96.8, 99.6, 100.7, 101.2, 101.6, 103.1, 103.2, 103.7, 103.9, 107.2, 107.3, 107.5 MHz -
FM Scope Station: 107.20 MHz, signal: 5/5 (59 dBuV) Max at: 71 kHz MIN: 3 kHz % above 75 kHz: 0,0352 Acquired: 2024/05/09 15:16:39 Total samples: 17063 Equivalent time: 0:14:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,8 dBr MIN: 5,0 dBr AVE: 6,04 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2024/05/09 15:16:38) Station: 107.20 MHz, signal: 5/5 (59 dBuV) 15:04 15:06 15:08 15:10 15:12 15:14 15:16 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality